Pump selection and pipe sizing for a 480-bed student residence
Size the rising main, select a transfer pump and a top-floor booster, and cut the pumping bill for a six-storey student residence that runs out of water every morning.
Industry project · for Kestrel Campus Housing, a student-accommodation operator with a 480-bed residence in Pretoria and a twin building planned in Pune
Kestrel's Pretoria residence has 480 beds over six floors. Municipal water fills a 60 m³ ground-level sump. A single 5.5 kW pump lifts it to a 40 m³ roof tank, and gravity feeds the floors from there. Both the sump and the roof tank are standard because city supply is cut for hours at a time, and the Pune twin will face the same intermittent supply.
Three things go wrong. Between 06:30 and 08:00 the roof tank empties faster than the pump refills it, and the top two floors get a trickle. The pump has burnt out twice in 18 months, and the maintenance team suspects it runs far from its best efficiency point. The electricity bill for pumping is R4,100 a month, which the finance manager thinks is too high.
The facts you have: - the roof tank outlet is 22.5 m above the sump water level; - the rising main is 68 m of 50 mm HDPE with six bends and two valves; - the top-floor showers are only 3.2 m below the roof tank outlet and need at least 1.0 bar to work well; - residents use about 150 L per person per day, and 45% of that happens in the morning peak.
Your job is to: - calculate the demand and peak flow; - size the rising main and the distribution pipes; - draw the system curve and select a pump from a real manufacturer curve; - size a small booster set for floors 5 and 6; - work out the running cost in rand and rupees.
You need no site visit. Everything is done by hand calculation and a spreadsheet, with an optional network check in the free EPANET software.
Done looks like a pump that refills the tank in under 3 hours, works near its best efficiency point, gives top-floor pressure of at least 1.0 bar, and costs less to run than today.
Demand and head-loss workbook + system curve with pump operating point + booster selection + energy cost comparison + short report with a schematic
Stack: Spreadsheet, Manufacturer pump curves (any public catalogue), EPANET (optional), Python with Matplotlib (optional)
- Correct demand and losses30
Daily demand, peak flow, pipe friction and fitting losses are calculated correctly with every assumption stated.
- Right pump, right point30
The chosen pump meets the refill target, its operating point is within 80–110% of best efficiency flow, and NPSH is checked.
- Top-floor pressure solved20
A booster or other solution gives at least 1.0 bar at the top-floor showers, with its duty point stated.
- Cost and report20
Monthly running cost is compared with today in rand and rupees, and a short report with a schematic explains the change.
Pass 60% · Merit 75% · Distinction 90%
Engineering Students
Diploma, B.Tech, B.E., BCA, MCA, or M.Tech students seeking practical experience.
Aspiring Developers
Developers who want to build proof-of-work capstone projects for tech resumes.
Job Seekers
Graduates looking for AI-evaluated code review & verified industry credentials.