Protection coordination study for an 11 kV overhead feeder

Calculate fault levels on a rural 11 kV feeder, set the breaker relay, recloser and spur fuses so they grade properly, plot the time-current curves and write the settings sheet the protection team will apply.

Core EngineeringElectrical Engineering
6 Guided Steps42h Internship TierSubmit: Python fault and TCC scripts + study report with fault table, CT selection, settings, coordination plots and margins + protection settings sheetVerified CertificateAI Rubric Graded
Program Overview

Industry project · for Ridgeline Power Distribution, a regional distribution utility; Feeder F7 out of its Hillcrest 33/11 kV substation

Feeder F7 leaves Hillcrest substation, which has two 10 MVA 33/11 kV transformers, and runs 14 km of overhead line to a cluster of villages and a dairy co-operative. There is a pole-mounted recloser at 6 km and eleven fused spurs feeding 46 distribution transformers of 100 to 500 kVA. Peak feeder load is about 240 A.

Customer minutes lost on F7 are the worst in the district. The outage log for the last year tells the story: - 31 of 44 breaker trips started on a spur, where the spur fuse should have cleared the fault without taking out the whole feeder; - the recloser and the substation relay both tripped on 9 faults beyond the recloser; - one broken conductor lay on dry ground for 40 minutes without any protection operating.

The protection engineer wants a proper study before the settings are changed. You have the network data: source fault level at 33 kV of 750 MVA at maximum and 400 MVA at minimum, transformer impedance 10% on 10 MVA, 11 kV neutral earthed through a resistor limiting earth-fault current to 750 A, and line impedance per kilometre for the main line and spurs, given in task 1.

You will build the network model, calculate maximum and minimum fault currents at every protection point, select CTs, set the substation IDMT overcurrent and earth-fault elements, set the recloser fast and delayed curves, choose spur fuse sizes, plot all the curves on log-log axes, and check grading margins. You will do it in Python from first principles, so no commercial software is needed.

Done looks like a study report and a settings sheet: fault table, CT and relay settings, recloser and fuse choices, time-current plots with margins marked, a sensitive earth-fault proposal for the broken-conductor case, and a list of what to verify on site. If one device cannot both protect its zone and grade with its neighbour, say so and propose a fix.

Per-unit fault calculationSymmetrical componentsIDMT relay settingRecloser and fuse coordinationTime-current curve plottingProtection settings documentation
What you submit

Python fault and TCC scripts + study report with fault table, CT selection, settings, coordination plots and margins + protection settings sheet

Stack: Python (numpy, matplotlib), Relay, recloser and fuse manufacturer curves, Spreadsheet, Markdown or Word

How it is graded
  • Correct fault levels25

    Three-phase and earth-fault currents at maximum and minimum source are calculated at every protection point with the per-unit working shown and checked by hand at one point.

  • Sound settings25

    Pickups, time multipliers and instantaneous elements are set so each device detects minimum faults in its zone, carries maximum load and grades with its neighbours.

  • Coordination proved25

    Time-current plots show every device pair with grading margins measured at the maximum fault current through both, and fuse saving or fuse blowing is chosen with reasons.

  • Broken-conductor case addressed10

    A sensitive earth-fault proposal is made with pickup and time set from the expected fault current, and its limitations are stated.

  • Field-ready settings sheet15

    The settings sheet lists every device, CT ratio and setting in the units the field team will enter, with a site verification list.

Pass 60% · Merit 75% · Distinction 90%

Learning Outcomes
Model a radial distribution feeder in per unit
calculate three-phase and earth-fault currents at maximum and minimum source
set IDMT overcurrent and earth-fault relays with correct grading margins
coordinate a recloser with upstream relays and downstream fuses using fuse saving
document settings so a field team can apply them