Motor energy audit and VFD retrofit business case for a spinning mill
Audit the fans and pumps of a spinning mill's humidification plant, model the savings from variable-frequency drives with the affinity laws, and write a business case the managing director can approve.
Industry project · for Bhavani Spinners, a 30,000-spindle cotton spinning mill near Coimbatore running 24 hours a day
Bhavani Spinners pays about ₹7 crore a year for roughly 95 lakh kWh. Its humidification plant, which keeps the spinning hall at the humidity cotton needs, is one of the largest loads after the ring frames. Today its fans run at full speed all the time and the airflow is controlled by dampers, and its pumps are throttled with valves. The maintenance manager has seen VFD retrofits at a neighbouring mill and wants to know if the numbers work here.
The plant has: - 4 supply-air fans at 37 kW, dampers set between 60% and 70% open; - 4 return-air fans at 22 kW; - 4 spray-water pumps at 15 kW with discharge valves half-closed; - 2 cooling-tower fans at 11 kW.
The mill runs 330 days a year, 24 hours a day. Energy costs about ₹7.80 per kWh on the HT tariff. The managing director will approve a retrofit only if simple payback is under 2 years and the savings can be checked afterwards.
You will build a motor register, analyse the spot readings an electrician took with a power analyser, model savings for each motor with the affinity laws while allowing for static pressure, specify the drives and their side effects on the mill's power quality, and write a business case with a measurement and verification plan. No site visit is needed: all the readings you need are in the task instructions, and the modelling is done in Python or a spreadsheet.
Done looks like a ranked list of retrofits with savings in kWh and rupees, a VFD specification an electrical contractor can price, and a two-page business case. Be honest where a retrofit does not pay back. Motors that are already lightly loaded or that serve a mostly static head can disappoint.
Motor register + loading analysis + savings model (code or spreadsheet) + VFD specification + two-page business case with M&V plan
Stack: Python (pandas, numpy) or a spreadsheet, Power analyser data (provided), Motor and VFD datasheets, Markdown or Word
- Correct loading analysis20
Every motor's loading, efficiency estimate and annual energy is calculated from the readings, with assumptions stated.
- Realistic savings model30
Savings use affinity laws with a system curve that includes static pressure or head, VFD losses are included, and results are given per motor in kWh and rupees.
- Usable specification20
The VFD specification covers rating, enclosure, harmonics, cable, bypass and controls well enough for a contractor to quote.
- Sound business case20
Payback, NPV and IRR are correct, the retrofits are ranked, weak candidates are dropped with reasons, and an M&V plan is included.
- Clear for the managing director10
The two-page summary is plain, leads with the money and the risks, and fits the 2-year payback rule.
Pass 60% · Merit 75% · Distinction 90%